User Tools

Site Tools


systems:battery

Medic Batterys

From: https://www.medicbatteries.com/

Family owned Medic Batteries has provided churches, hospitals, schools, law enforcement 
agencies, theaters, TV/radio stations, home owners, and more with dependable, long-lasting
bulk Energizer batteries, bulk Duracell batteries, and now bulk Rayovac batteries and more
since 1993. We pride ourselves on being honest, easy to work with, reliable, and experienced
battery experts ready to help by phone to fill orders, solve problems and answer questions.

Dead UPS Batteries? There’s a Cheaper Way

From: http://www.stevejenkins.com/blog/2012/12/dead-ups-batteries-theres-a-cheaper-way/

UB1290 9AH version of "APC" RBC2


1 . So whenever I remove multiple old batteries from a UPS, the first thing I do is 
shake them individually. If they rattle, they’re dead. Go ahead and toss recycle them (in fact, 
some battery stores will pay you for your dead RBC-style batteries). 
2. If they pass the shake test, I connect them to one of my CTEK 12 volt battery chargers (any 
car charger will do – car batteries are also 12 volts). If my charger doesn’t light up, it means 
the battery’s posts aren’t connected internally, and so the battery is dead. 
3. If the charger’s lights rapidly switch between “fully charged” and “charging,” then something’s 
wonky inside the battery, and it’s dead. 
4. But if it charges, and stays charged, put it in the “good” pile.

UPS Battery

From: http://www.expertpower.us/EXP1290-12-Volt-9-Amp-Rechargeable-Battery

2017-08-28
Start using and monitoring quality of Expert batteries. Switched from SigmasTek at batterysharks 
to test longevity.


Type	TerminalVoltage	AH	L	W	H	Need	Weight
RBC7	NB	12	18	7.13	3.00	6.59	2	26.00
SP12-22	NB	12	22	7.13	3.00	6.59	1	13.50
EXP12180NB	12	18	7.12	3.03	6.3	1	11.68

RBC2	F2	12	7.5	5.95	2.56	3.70	1	5.06
SP12-9HRF2	12	9	5.95	2.56	3.70	1	6.05
EXP1290	F2	12	9	5.9	2.5	3.7	1	5.53

From: http://www.batterysharks.com/

Been using for some time RBC2 replacement; batteries do not last very long and Batterysharks says if voltage of battery is above 11 then battery is good. I dissagree. Switched to 9 Hr batteries in hopes to get more longevity.

From: http://www.gobti.com/

Very Expensive for UPS RBC2

From: http://www.gruberpower.com/12-volt-7-amp-hour-ah-battery

Great Specs and Crossrefernece tables

From: https://www.upsforless.com/cart.aspx

	
APC SmartUPS 750VA Tower UPS with LCD Display, Refurbished (SMT750)
For: 160.00 with Shipping
systems/battery.txt · Last modified: 2018/06/19 17:39 by superwizard